Safety 2
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
GENERAL SAFETY
Electrically powered utility pumps normally give many
years of trouble-free service when correctly installed,
maintained, and used. However, unusual circumstances
(interruption of power to the pump, dirt/debris, flooding
that exceeds the pump’s capacity, electrical or mechani-
cal failure in the pump, etc.) may prevent your pump
from functioning normally. To prevent possible water
damage due to flooding, consult your retailer about a
secondary AC pump, a DC backup pump, and/or a high
water alarm. See the “Troubleshooting Chart” in this
manual for information about common pump problems
and remedies.
For more information, see your retailer or call Flotec
customer service at 1-800-365-6832.
1. Know the pump application, limitations, and poten-
tial hazards.
Do not use in explosive atmospheres.
Pump water only with this pump. Failure to follow
this warning can result in personal injury and/or
property damage.
2. Make certain power source conforms to requirements
of your equipment.
3. Disconnect power before servicing.
4. Release all pressure within system before servicing
any component.
5. Drain all water from system before servicing.
6. Secure discharge line before starting pump. An unse-
cured discharge line will whip, possibly causing per-
sonal injury and/or property damage.
7. Check hoses for weak or worn condition before each
use, making certain all connections are secure.
8. Periodically inspect pump and system components.
Keep pump and system free of debris and foreign
objects. Perform routine maintenance as required.
9. Provide means of pressure relief on pumps whose dis-
charge line can be shut-off or obstructed.
10.Personal Safety:
a. Wear safety glasses at all times when working
with pumps.
b. Keep work area clean, uncluttered and properly
lighted – replace all unused tools and equipment.
c. Keep visitors at a safe distance from the work area.
d. Make workshop child-proof – with padlocks, mas-
ter switches, and by removing starter keys.
11. When wiring an electrically driven pump, follow all
electrical and safety codes, as well as most recent
National Electrical Code (NEC) and Occupational
Safety and Health Act (OSHA).
Pump motor is equipped with an auto-
matic resetting thermal protector and may restart
unexpectedly.
12. Risk of electric shock. This equipment is
only for use on 115 volt (single phase) and is
equipped with an approved 3-conductor cord and
3-prong, grounding-type plug.
To reduce risk of electric shock, be cer-
tain that it is connected to properly grounded,
grounding-type receptacle.
Where a 2-prong wall receptacle is encountered, it
must be replaced with properly grounded 3-prong
receptacle installed in accordance with the National
Electrical Code and local codes and ordinances.
13.All wiring should be performed by a qualified
electrician.
14.Protect electrical cord from sharp objects, hot sur-
faces, oil, and chemicals. Avoid kinking cord. Replace
or repair damaged or worn cords immediately.
15.Use wire of adequate size to minimize voltage drop at
motor. Refer to most recent National Electrical Code.
16.Do not touch an operating motor. Modern motors can
operate at high temperatures.
17.The oil-filled motor was not designed for use in
water containing fish. Do not use this pump in water
with fish present.
SPECIFICATIONS
Power supply required................................115V, 60 HZ.
Liquid Temp. Range ..............................Max. 77°F (25°C)
Operation Position ...............................................Vertical
Individual Branch Circuit Required ....................15 Amp
Operating Depth Beginning min.........................3/4"
(water level) Ending max.............................1/4"
Discharge ...............................................1" NPT (25 mm)
Pump water only with this pump.
NOTICE: This unit is not designed as a waterfall or fountain
pump, or for applications involving salt water or brine! Use
with waterfalls, fountains, salt water or brine will void
warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.
DESCRIPTION
The submersible pump is designed for water removal in
home applications. Pump can be used for emergency
service and dewatering. Unit is constructed of hi-impact
corrosion resistant plastic. Screened inlet prevents large
solids from entering pump.
NOTICE: This unit is not designed for applications involv-
ing salt water or brine! Use with salt water or brine will
void warranty.
PERFORMANCE
GPH (LPH) AT TOTAL FEET (M)
3' 5' 10' 15' 18' 20' 22'
(0.91) (1.52) (3.05) (4.57) (5.49) (6.09) (6.70)
1600 gal 1524 gal 1260 gal 924 gal 648 gal 372 gal 0 gal
(6 057 L) (5 769 L) (4 770 L) (3 498 L) (2 453 L) (1 408 L) (0 L)

Questions and Answers:

Flotec IntelliPump FP0S1775A Specifications

General IconGeneral
ModelFP0S1775A
CategoryWater Pump
Voltage115V
Phase1
Max Head25 ft
Cord Length10 ft
MaterialThermoplastic
Thermal ProtectionYes
TypeSubmersible
Horsepower0.75 HP
Discharge Size1.25 in
Outlet Size1.25 in
Switch TypeVertical Float

Summary

Thermoplastic Submersible Utility Pumps

FPSC1725X Utility Pump Overview

Heavy-duty, epoxy coated, cast aluminum utility pump with 1/4 HP motor and lifetime warranty.

FPOS1775A IntelliPump Overview

Automatic utility pump with electronic control, 1/4 HP motor, 2-year warranty, and auto on/off feature.

FPOS1300X Tempest Utility Pump Overview

Multi-purpose submersible pump with 1/6 HP motor, suitable for emergency and dewatering.

FPOS1250X Utility Pump Overview

Plastic construction utility pump with 1/6 HP motor and 1-year warranty.

Safety Information

General Safety Precautions

Essential safety guidelines for pump usage, installation, and electrical handling.

Electrical Safety Warnings

Critical warnings regarding electric shock, grounding, and automatic motor restarts.

Pump Specifications

Power Supply and Operation Requirements

Details on power requirements, temperature range, operation position, and circuit requirements.

Performance Data

Pump performance data including GPH at different total feet of head.

Installation and Operation

Installation Guidelines

Step-by-step instructions for correctly installing the submersible utility pump.

Pump Operation and Automatic Functionality

How to operate the pump, including automatic functions and overload protection.

Airlock Prevention and Resolution

Information on identifying and resolving airlock issues in the pump.

Repair Parts and Troubleshooting

Repair Parts Identification

List and diagram of common repair parts for the utility pump with part numbers.

Troubleshooting Common Pump Issues

Guidance on diagnosing and correcting common pump problems like no start or low water delivery.

Warranty Information

Warranty Period for Flotec Products

Overview of warranty periods for different Flotec pump models.

General Warranty Terms and Conditions

Standard terms, conditions, limitations, and exclusions for Flotec product warranties.

Related product manuals