Argus Ball Valve EK, FK and HK Operating Manual – BA1000 EN
3 Product Description
Page 30 of 67
Connecting plate design in accordance with EN ISO 5211 for easy assembly with
actuators
Sizes available from DN 15 (1⁄2″) to DN 900 (36″) with full or reduced bore
Supported pressure classes from PN 10 to PN 250 (ASME Classes 150 to 2500)
Standard temperature range from −50 °C to +400 °C (Argus Ball Valves with special
features excluded)
Note that the actual design features of the Argus Ball Valve are specified in the
delivery documents.
3.3 Scope of Delivery
The scope of delivery normally includes the following components:
Argus Ball Valve (usually operated in open position)
Wrench (only up to DN 200)
Protective caps
Operating manual including the EU Declaration of Conformity and Incorporation
Order related documents (e.g., material certifications)
Documents required by law
Note that the actual scope of delivery is stated in the delivery note.