Argus Ball Valve EK, FK and HK Operating Manual – BA1000 EN
5 Installation
Page 35 of 67
5.4 Installing the Argus Ball Valve via a Welded Connection
1. Transport the Argus Ball Valve to the assembly location using lifting devices
suitable for the weight and the size of the Argus Ball Valve.
2. Remove the protective caps.
3. Clean the piping connection and the welding ends of the Argus Ball Valve.
4. Remove paint and rust in the area of the welded joints so there is a clean metal
surface.