Brand | Fluke Biomedical |
---|---|
Model | IMPULSE 6000D |
Category | Measuring Instruments |
Language | English |
Outlines the terms and conditions of the product warranty.
States copyright and usage restrictions for the publication.
Grants limited permission for reproducing manual content for training.
Provides instructions for receiving and inspecting the instrument upon arrival.
Offers contact information for technical assistance and procedures for filing claims.
Details eligibility and conditions for product returns, refunds, and credits.
Specifies the fees applied for product returns based on the return timeframe.
Outlines the steps required for returning instruments for service or credit.
States that information is subject to change and limits Fluke Biomedical's responsibility.
Identifies the place of manufacture for the Impulse 6000D and 7000DP Analyzers.
Explains the meaning of Warning and Caution symbols and their implications.
Provides essential safety precautions for operating the Analyzer to prevent injury.
Details critical safety measures related to power, patient connection, and voltage handling.
Identifies and describes the controls and connectors on the top surface of the Analyzer.
Details the input/output ports and connectors located on the rear panel of the Analyzer.
Explains the procedure for powering the Analyzer on and off, including initial charging.
Measures the energy output accuracy of defibrillators.
Allows modification of test waveform parameters like amplitude and rate.
Verifies the defibrillator's synchronization response to ECG signals.
Measures the time taken for a defibrillator to reach a specified charge level.
Guides the user through configuring the Analyzer for pacemaker analysis.
Verifies continuous mode pacemaker output with simulated ECG signals.
Checks demand mode pacemaker interaction with simulated ECG signals.
Determines the ECG signal amplitude required to trigger the pacemaker.
Assesses pacemaker's ability to sense ECG activity after paced or sensed events.
Explains how to connect ECG leads from monitors to the Analyzer's posts.
Configures a standard ECG signal with adjustable rate and amplitude.
Generates special test signals for defibrillator monitor performance evaluation.
Simulates varying ECG conditions for testing pacer response in demand mode.
Simulates asystole conditions for testing pacer response to simulated heartbeats.
Allows simulation of various cardiac arrhythmia waveforms for testing.
Configures pacing signals for testing transvenous pacing modes.
Details how the Analyzer simulates R-Waves and allows adjustable parameters.
Verifies the pacemaker's ability to filter AC line frequency noise.
Configures battery options including power off, charging, and training.
Adjusts display contrast, backlight, and beeper volume settings.
Shows manufacturing date, firmware version, and serial number.
Describes how to control the Analyzer remotely using Ansur software.
Provides instructions and precautions for cleaning the Analyzer's exterior.
Offers guidance on how to maintain optimal battery capacity over time.
Lists available accessories for the Impulse 6000D/7000DP Analyzer.
Lists general operating and physical characteristics of the Analyzer.
Details the technical specifications for defibrillator testing functions.
Provides specific parameters and measurements for synchronization testing.
Outlines the parameters and capabilities for simulating ECG waveforms.
Details the technical specifications for the 7000DP's pacemaker testing.
Lists specifications for various pacemaker tests like pulse rate, width, and energy.
Provides specifications for pacer sensitivity and refractory period measurements.
Explains how to use the Ansur plug-in software for executing tests on the Analyzer.
Details how to run defibrillator tests using the Ansur software interface.
Describes how to perform pacemaker tests using the Ansur software.
Explains how to simulate ECG waveforms for testing using Ansur.
Details how to conduct battery performance tests using the Ansur software.
Guides the user on creating, modifying, and reviewing test templates in Ansur.
Describes parameters and data for the Energy Measurement test.
Details parameters and measurements for the Charge Time test.
Outlines parameters and measurements for the Synchronization Time test.
Explains parameters and measurements for the Pacer Parameter test.
Details parameters and measurements for Pacer Refractory Period tests.
Outlines parameters and measurements for Pacer Sensitivity tests.
Describes parameters for simulating patient response to pacemakers.
Details parameters for testing demand mode pacing over a range of BPM rates.