General Specifications
25
General Specifications
Maximum voltage between any terminal
and Earth Ground ............................................................ 600 V
Fuse protection for A input ............................................ 11 A, 1000 V, IR 17 kA
Display (LCD) ................................................................... 6000 counts, updates 3/sec
Battery Type .................................................................... 2 AAA, NEDA 24A, IEC LR03
Battery Life ...................................................................... 200 hours minimum
Temperature
Operating ...................................................................... 0 °C to 40 °C
Storage ......................................................................... -30 °C to 60 °C
Relative Humidity
Operating Humidity ....................................................... Non-condensing when <10 °C;
90 % at 10 °C to 30 °C;
75 % at 30 °C to 40 °C
Operating Humidity, 40 M Range ............................... 80 % at 10 °C to 30 °C;
70 % at 30 °C to 40 °C
Altitude
Operating ...................................................................... 2000 m
Storage ......................................................................... 12,000 m