Page 15
Maximum Voltage
Between any Terminal
and Earth Ground:
600 V
Display: 3 3/4-digits, 6000 counts, updates 4/sec
Operating Temperature: -10°C to 50°C (14°F to 122°F)
Storage Temperature: -40°C to 60°C (-22°F to 140°F)
Temperature
Coefficient:
0.1 x (specified accuracy)/°C (<18 °C or
>28 °C)
Operating Altitude: 2,000 m
Storage Altitude: 10,000 m
Relative Humidity: 95 % to 30 °C
75 % to 40 °C
45 % to 50 °C
Battery Type: 9 Volt Alkaline, ANSI 1604A / IEC 6F22
Battery Life: Alkaline: 300 hours typical, without
backlight
Shock: 1 Meter drop per IEC 61010-1-2001
Vibration: Per MIL-PRF-28800 for Class 2
instrument
Size (H x W x L): 6.58 in X 3.35 in X 1.81 in (167.1 mm X
85.1 mm X 46.0 mm)
Weight: 13.0 oz (404 g)
Safety: Complies with ANSI/ISA 82.02.01 (61010-
1) 2004, CAN/CSA-C22.2 No 61010-1-04,
UL 61010-1 (2004) and IEC/EN 61010-1
2
nd
Edition for measurement Category III,
600 V, Pollution Degree 2, EMC
EN61326-1.
EMI Regulations: Complies with FCC Part 15, Class B
Certifications:
P $;
TUV, (N10140), UL and VDE

Other manuals for Fluke 113