Function Input Impedance (Nominal)
k Chek
~3 kΩ <300 pF
Common Mode Rejection Ratio (1 kΩ Unbalanced)
k Chek
>60 dB at dc, 50 or 60 Hz
Open Circuit Test Voltage Full Scale Voltage
Ω
<2.7 V dc <0.7 V dc
R <2.7 V dc 2.000 V dc
Short Circuit Current
Ω
<350 μA
R <1.0 mA
MIN MAX Recording Accuracy and Response Time
Specified accuracy of the measurement function ±40 counts in kChek for
changes >500 ms in duration, ±12 counts in Ohms for changes >325 ms in
duration. Typical 100 ms response to 80 %. Response time not specified for
Capacitance.