Insulation Multimeter
Electrical Specifications
35
Electrical Specifications
AC Voltage Measurement
Accuracy (all 1587 models)
Range Resolution
50 Hz to 60 Hz
±(% of Rdg + Counts)
60 Hz to 5000 Hz
±(% of Rdg + Counts)
600.0 mV 0.1 mV
±(1 % + 3) ±(2 % + 3)
6.000 V 0.001 V
±(1 % + 3) ±(2 % + 3)
60.00 V 0.01 V
±(1 % + 3) ±(2 % + 3)
600.0 V 0.1 V
±(1 % + 3) ±(2 % + 3)
[1]
1000 V 1 V
±(2 % + 3) ±(2 % + 3)
[1]
[1] 1 kHz bandwidth.
Low-Pass Filter Voltage (all 1587 models)
Range Resolution
50 Hz to 60 Hz
±(% of Rdg + Counts)
60 Hz to 400 Hz
±(% of Rdg + Counts)
600.0 mV 0.1 mV
±(1 % + 3)
+(2 % + 3)
-(6 % - 3)
6.000 V 0.001 V
±(1 % + 3)
+(2 % + 3)
-(6 % - 3)
60.00 V 0.01 V
±(1 % + 3)
+(2 % + 3)
-(6 % - 3)
600.0 V 0.1 V
±(1 % + 3)
+(2 % + 3)
-(6 % - 3)
1000 V 1 V
±(2 % + 3)
+(2 % + 3)
-(6 % - 3)