How to Clean
Clean the Product with a soft cloth, mild soap, and water.
W Caution
To avoid damage, do not clean with abrasives or
solvents.
Specifications
General
Calibration Cycle ................ 2 years
Warranty............................. 1 year
Dimensions......................... 119 mm x 86 mm x 38 mm
(4.69 in x 3.39 in x 1.5 in)
Weight ................................ 280 g (0.6 lb)
Output Cable Length .......... 1.9 m (6.2 ft)
Electrical
Direct input
Voltage ........................... 0 V dc to ±10 V dc
Input Impedance............. 909 k (see block diagram for details)
Cable Diameter .............. 3 mm to 6 mm
Connection ..................... Spring-loaded terminal for solid or
braided wires
minimum: 0.2 mm² (AWG 24)
maximum: 1.5 mm² (AWG 16)
Voltage Divider Input
Voltage ........................... 0 V dc to ±1000 V dc
Input Impedance............. 20 M (see block diagram for details)
Connector....................... 4 mm safety socket
Shop for Power Metering products online at:
1.888.610.7664
www.PowerMeterStore. com

Other manuals for Fluke 1736/FPC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 1736/FPC and is the answer not in the manual?

Fluke 1736/FPC Specifications

General IconGeneral
BrandFluke
Model1736/FPC
CategoryData Loggers
LanguageEnglish

Related product manuals