EasyManuals Logo

Fluke 187 Getting Started

Fluke 187
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
i
Table of Contents
Title Page
Introduction....................................................................................................................1
Contacting Fluke ........................................................................................................... 1
Safety Information ......................................................................................................... 1
Rotary Switch ................................................................................................................ 4
Pushbuttons .................................................................................................................. 4
Understanding the Display ............................................................................................ 9
Setup Selections ........................................................................................................... 14
Parts.............................................................................................................................. 16
Safety and Compliances................................................................................................ 16
Feature Summary.......................................................................................................... 17
Physical Specifications.................................................................................................. 18
Basic Specifications....................................................................................................... 19
Detailed Accuracy Specifications .................................................................................. 20
Frequency Counter Sensitivity....................................................................................... 26
Burden Voltage (A, mA, µA).......................................................................................... 26
Input Characteristics...................................................................................................... 27

Other manuals for Fluke 187

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 187 and is the answer not in the manual?

Fluke 187 Specifications

General IconGeneral
Frequency Range0.5 Hz to 1 MHz
Safety RatingCAT III 1000V, CAT IV 600V
AC Voltage Range0.1 mV to 1000 V
AC Current Range0.1 µA to 10 A
DC Voltage Accuracy±(0.025% + 2)
AC Voltage Accuracy0.4% + 40 digits (True RMS)
Resistance Accuracy±(0.05% + 2)
Temperature Range-200°C to 1350°C
Operating Temperature-20 °C to +55 °C
Battery Type9V (NEDA 1604)