FLUKE 27/FM MULTIMETER OPERATOR'S MANUAL
CONTENTS
SECTION TITLE
PAGE
INTRODUCTION
1
UNPACKING THE INSTRUMENT
2
MULTIMETER SAFETY
2
BATTERY INSTALLATION AND REPLACEMENT
3
GETTING STARTED QUICKLY
POWER-UP OPTIONS AND TESTS
5
OPERATING FEATURES
5
MEASUREMENT TECHNIQUES AND CONSIDERATIONS
10
True RMS vs Average-Responding Meters
10
Measuring Voltage, AC/DC
10
Measuring Current, AC/DC
12
Current Measurement Error Calculations
12
Measuring Resistance
13
Diode and Continuity Testing
13
Measuring Conductance
14
Leakage Testing
14
USING THE ANALOG BAR GRAPH
15
Nulling
15
Contact Bounce
15
Checking Capacitors
16
Noisy Resistance Measurements
16
MAINTENANCE
16
General Maintenance
16
Tilt Stand Adjustment
17
Fuse Test
17
Fuse Replacement
17
SPECIFICATIONS
18
INTRODUCTION
The Fluke 27/FM Multimeter (hereinafter, also referred to as the "DMM" or
"meter") is a true rms, digital multimeter that provides unsurpassed
performance and operator safety in the most demanding working conditions. It
meets MIL-T-28800 Type II, Class 2, Style A specifications for shock,
vibration, humidity, and water resistance. The meter is powered by a 9V
battery with a life of 750 hours.
The Fluke 27/FM combines the precision of a digital meter with the speed and
versatility of an analog bar graph. Its 3200-count, digital display offers
better resolution than a conventional 3-1/2 digit, 2000-count display.
The 80K-6 High Voltage Probe that is shipped with the meter extends the
voltage measurement capability of the meter to 6000V. A 1000:1 voltage

Related product manuals