EasyManuals Logo

Fluke 287 Calibration Manual

Fluke 287
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
True-rms Digital Multimeters
Safety Information
3
ANSI/ISA 82.02.01 (61010-1) 2004
UL 61010B (2003)
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1 2
nd
Edition Pollution Degree 2
EMC EN 61326-1
Measurement Category III, 1000V, Pollution Degree 2
Measurement Category IV, 600 V, Pollution Degree 2
XWWarning
To avoid possible electric shock or personal injury, follow these
guidelines:
Use this Meter only as specified in this manual or the
protection provided by the Meter might be impaired.
Do not use the Meter if it is damaged. Before you use the
Meter, inspect the case. Look for cracks or missing
plastic. Pay particular attention to the insulation
surrounding the connectors.
Make sure the battery door is closed and latched before
operating the Meter.
Remove test leads from the Meter before opening the
battery door.
Inspect the test leads for damaged insulation or exposed
metal. Check the test leads for continuity. Replace
damaged test leads before using the Meter.
Do not apply more than the rated voltage, as marked on
the Meter, between the terminals or between any
terminal and earth ground.
Never operate the Meter with the cover removed or the
case open.
Use caution when working with voltages above 30 V ac
rms, 42 V ac peak, or 60 V dc. These voltages pose a
shock hazard.
Use only the replacement fuses specified by the manual.
Use the proper terminals, function, and range for
measurements.
Avoid working alone.
When measuring current, turn off circuit power before
connecting the Meter in the circuit. Remember to place
the Meter in series with the circuit.
When making electrical connections, connect the
common test lead before connecting the live test lead;
when disconnecting, disconnect the live test lead before
disconnecting the common test lead.

Table of Contents

Other manuals for Fluke 287

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 287 and is the answer not in the manual?

Fluke 287 Specifications

General IconGeneral
Data holdYes
Product typeDigital multimeter
Product colorGrey, Yellow
Frequency range0 - 999.99 kHz
DC current range0 - 10 A
DC voltage range0 - 1000 V
Resistance range0 - 500000000 Ω
Capacitance range0 - 100000 nF
Resolution (AC voltage)0.001 mV
Basic accuracy (frequency)0.005%
Basic accuracy (DC current)0.05%
Basic accuracy (DC voltage)0.025
Temperature measurement range-200 - 1350 °C
Battery typeAA
Power sourceBattery
Battery technologyAlkaline
Number of batteries supported6
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)-20 - 55 °C
Operating relative humidity (H-H)0 - 90 %
Display digits4.5 digits
Weight and Dimensions IconWeight and Dimensions
Depth60 mm
Width102 mm
Height222 mm
Weight870.9 g