EasyManua.ls Logo

Fluke 302+ - Jaw Maintenance; How to Clean the Product; Specifications; Electrical Specifications

Fluke 302+
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Clamp Meter
Maintenance
7
Maintenance
Clean the Product
Caution
To prevent possible damage to the Product or to equipment
under test, do not use abrasive cleaners. They will damage the
case.
To clean the Product, use a cloth with a mild cleaning solution.
Battery Replacement
 Warning
To prevent possible explosion, fire, or personal injury, replace
the batteries when the low battery indicator (B) shows to
prevent incorrect measurements.
Caution
To prevent possible damage to the Product or to equipment
under test:
Remove batteries to prevent battery leakage and damage to
the Product if it is not used for an extended period.
Be sure that the battery polarity is correct to prevent battery
leakage.
To change the batteries, see Figure 2:
1. Make sure the Product is off.
2. Turn over the Product to access the battery compartment door screw.
3. Use a flat-head screwdriver to loosen the battery compartment door screw and lift off
the battery compartment door.
4. Replace the two AAA batteries. Make sure to use the correct polarity when you put
the batteries into the battery compartment door.
5. Reattach the battery compartment door.
6. Tighten the battery compartment door screw.
AAA
hfj007.eps
Figure 2. Battery Replacement