(A dc)
Range 40.00 A
600.0 A
40.00 A
600.0 A
1000 A
Resolution 0.01 A
0.1 A
0.01 A
0.1 A
1A
Accuracy 1.6 % ±6 digit
[40 A]
1.5 % ±5 digit
[600 A]
1.6 % ±6 digit
[40 A]
1.5 % ±5 digit
[600/1000 A]
V
(V ac)
Range 600.0 V
Resolution 0.1 V
Accuracy 1.5 % ±5 digit (20 Hz-500 Hz)
AC Response rms
V
(V dc)
Range 600.0 V
Resolution 0.1 V
Accuracy 1.5 % ±4 digit
O
Range 400.0 Ω
4000 Ω
Resolution 0.1 Ω
1 Ω
Accuracy 1 % 5.0
Function Parameter 317 319