Table 6. Test Failures (without Cable ID Unit)
Failure Display Description
Short*
(UTP/FTP/STP)
abm10f.eps
Displays shorted wires and the most likely distance
to the short.
Short*
COAX
?
SHORT
abm11f.eps
Displays the most likely distance to the short.
Open
OPEN
OPEN
OPEN
OPEN
abm12f.eps
Displays open wires and whether the open is at the
near or far end of the cable.
Split Pair
abm13f.eps
Display wire pairings that are incorrect based on
the cable selected.
* A short greater than zero ohms causes the test tool to display a legth greater than the actual distance to the