EasyManua.ls Logo

Fluke 701 - AC Voltage Measurement

Fluke 701
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
701/702
Users Manual
88
AC Voltage Measurement
FREQUENCY RANGE
MODEL 701 AND 702
(% OF READING + NUMBER OF COUNTS)
1 YEAR 2 YEAR
20 to 40 Hz 2% + 10 2% + 10
40 to 500 Hz 0.5% + 5 0.5% + 5
500 Hz to 1 kHz 2% + 10 2% + 10
1 kHz to 5 kHz 10% + 20 10% + 20
Specifications apply for 10% to 100% of voltage range
Ranges : 1.1000 V, 11.000 V, 110.00 V, 300.0 V rms
Resolution: 11.000 counts in all ranges except 300V; 3,000 counts on 300V range.
Input Impedance: 5 M and <100 pF
Temperature Coefficient: 10% of spec/°C in the ranges -10 to 18°C and 28 to 50°C
Input Coupling: ac
Maximum Input Voltage: 300 V rms
For frequencies >1 kHz, the minimum voltage is 0.5 V