EasyManua.ls Logo

Fluke 8502A - Options and Accessories Listing; System Specifications

Fluke 8502A
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8502A
1-11.
0
ptions and Accessories
1-12. Remote interfaces,
AC converters, a current con-
verter and an ohms converter are
among
the numerous
options and accessories available
for the 8502A. Refer to
Tables
1-1
and
1-2
for complete listings.
AC
conversion
can
be accomplished with
eidier
an
ac
averaging module
(-01)
or
a true RMS module (—
09A). Any one of
three
remote
interface modules
(—05,
—06, —07)
may
be installed at one
time; the isolator module (—08A) must then be installed to
maintain guarding
of analog and
high
quality busses during
remote operations.
Maximum
interfacing with digital sys-
tems is thus
realized. Calibration downtime is reduced
through the
use
of a
calibration
memory module
(-04);
correction factors may be entered from the front panel,
providing automatic correction for further measurements.
Table
1-1.
8502A Options
Option IMo.
Name
Notes
01
AC/DC Converter (Averaging)
1,3
02 Ohms Converter
03 Current
Shunts
3
04
Calibration Memory
05
IEEE
Standard
488-1975 Interface
2
06 Bit Serial Asynchronous interface 2
07
Parallel Interface
2
08A Isolator
4
09A AC/DC Converter
(True
RMS)
1,
3
16 Front—
Rear
Switchabie Input 5
17 Rear Input
1}
Options 01 and
09A
cannot be
installed
simultaneously.
2)
Only one of Options
05,
06,
and 07
can be installed at any time.
3)
For die
AC
portion of Option 03 to
operate, either Option 01 or 09A
must be installed.
4)
Option 08A must be installed for
remote
operations.
5}
Option
16 must be factory
installed.
1-2
Analog inputs from
a remote position are
permitted when
Rear Input (Option—
17)
is installed.
Selectable front or
rear analog inputs
are available
with Option
—16.
1-13.
SPECIFICATIONS
1-14.
Mainframe
specifications with DC Volts
and DC
Ratio measurement capability are presented in Table
1-3.
Optional
functirjn specifications are supplied with the
respective option modules and included in Section
6. The
table of
specifications presented here
is
divided
into three
parts:
1 .
General Specifications.
2. Accuracy.
3. Instrument Operating Characteristics.
Table
1-2. 8502A
Accessories
Model or
Part No.
Name
M04-205-600 Rack
Ear
Mounting
Assembly
MOO-260-010 18-inch Rack
Slides
MOO-280-610 24-inch
Rack Slides
80F-5 Fligh Voltage Probe
80F-15 High Voltage Probe
81RF
High Frequency
Probe
82RF High Frequency Probe
KDM1 Keyboard Display Module w/Cable
Y8001 IEEE
Std. Cable, 1 Meter Length
Y8002 IEEE
Std.
Cable,
2
Meter
Length
Y8003
IEEE Std. Cable, 4 Meter Length
MIS-7011K* Extender
Assembly
MIS-7190K* Static Controller
M!S-7191K*
Test Module
MIS-7013K* Bus Interconnect and Monitor
*For use during service
or repair

Related product manuals