19
Table 4. Calibration Adjustment Steps
Function
(Switch Position)
Adjustment Step Input Value
(AC Volts)
C-01 600.0 mV, 60 Hz
C-02 600.0 mV, 20 kHz
C-03 6.000 V, 60 Hz
C-04 6.000 V, 20 kHz
C-05 60.00 V, 60 Hz
C-06 60.00 V, 20 kHz
C-07 600.0 V, 60 Hz
C-08 600.0 V, 10 kHz
(DC Volts)
C-09 6.000 V
C-10 60.00 V
C-11 600.0 V
(DC Millivolts)
C-12 600.0 mV
C-13 60.00 mV
(Ohms)
C-14 600.0 Ω
C-15 6.000 kΩ
C-16 60.00 kΩ
C-17 600.0 kΩ
C-18 6.000 MΩ
C-19 0.000 Ω
C-20 50.0 MΩ
(Diode Test)
C-21 3.000 V
(Amps)
C-22 6.000 A, 60 Hz
C-23 6.000 A dc
(Amps)
C-24 60.00 mA, 60 Hz
C-25 400.0 mA, 60 Hz
C-26 60.00 mA dc
C-27 400.0 mA dc
(Microamps)
C-28 600.0 μA, 60 Hz
C-29 6000 μA, 60 Hz
C-30 600.0 μA dc
C-31 6000 μA dc