8845A/8846A
Programmers Manual
32
Table 13. Measurement Configuration Command Summary (cont.)
Command
[1]
Description
:FILTer
[:STATe] {OFF|ON}
[:STATe]?
:DIGItal
[:STATe]{OFF|ON}
[:STATe]?
:IMPedance
:AUTO {OFF|ON}
:AUTO?
:NPLCycles {0.02|0.2|1|10|100|
MINimum|MAXimum}
:NPLCycles? [MINimum|MAXimum]
:RANGe {<range>|MINimum|MAXimum}
:AUTO {OFF|ON}
:AUTO?
:RANGe? [MINimum|MAXimum]
:RESolution {<resolution>|MINimum|MAXimum}
:RESolution? [MINimum|MAXimum]
CURRent
:AC
:BANDwidth {3|20|200|MINimum|MAXimum}
:BANDwidth?
:RANGe {<range>|MINimum|MAXimum}
:AUTO {OFF|ON}
:AUTO?
:RANGe? [MINimum|MAXimum]
:RESolution {<resolution>|MINimum|MAXimum}
:RESolution? [MINimum|MAXimum]
[:DC]
:FILTer
[:STATe] {OFF|ON}
[:STATe]?
:DIGItal
[:STATe]{OFF|ON}
[:STATe]?
:NPLCycles {0.02|0.2|1|10|100|
MINimum|MAXimum}
:NPLCycles? [MINimum|MAXimum]
:RANGe {<range>|MINimum|MAXimum}
:AUTO {OFF|ON}
:AUTO?
:RANGe? [MINimum|MAXimum]
:RESolution {<resolution>|MINimum|MAXimum}
:RESolution? [MINimum|MAXimum]
RESistance
:FILTer
[:STATe] {OFF|ON}
[:STATe]?
:DIGItal
[:STATe]{OFF|ON}
[:STATe]?
Path to analog filter
Activates or deactivates 3-pole analog filter
Retrieve the present analog filter setting
Path to digital filter
Activates or deactivates digital filter
Retrieve the present digital filter setting
Path to input impedance selection
Turn auto-impedance mode off or on
Retrieve present setting of auto impedance
Set integration time for selected function
Retrieve integration time for selected function
Set dc voltage range
Disable/enable Autoranging
Retrieve present autorange setting
Retrieve the present range setting
Set resolution for dc voltage measurement
Retrieve dc voltage measurement resolution
Path to configure current measurement range
Path to ac current range
Select filter
Retrieve present filter setting
Set ac current range
Disable/enable Autoranging
Retrieve present autorange setting
Retrieve the present range setting
Set resolution for ac current measurement
Retrieve ac current measurement resolution
Path to dc current range
Path to analog filter
Set analog filter off or on
Retrieve the present analog filter setting
Path to digital filter
Activates or deactivates digital filter
Retrieve the present digital filter setting
Set integration time for selected function
Retrieve integration time for selected function
Set dc current range
Disable/enable Autoranging
Retrieve present autorange setting
Retrieve the present range setting
Set resolution for dc current measurement
Retrieve dc current measurement resolution
Path to 2–wire resistance measurement range
Path to analog filter
Set the analog filter off or on
Retrieve the present analog filter setting
Path to digital filter
Activates or deactivates digital filter
Retrieve the present digital filter setting