EasyManua.ls Logo

Fluke DTX-MFM2 - Autotest in Far End Source Mode

Fluke DTX-MFM2
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DTX-MFM2/GFM2/SFM2 Fiber Modules
Users Manual
36
Autotest in Far End Source Mode
Use Far End Source mode to measure loss at one
wavelength on individual fibers.
Far End Source mode requires a stand-alone optical source.
Figure 15 shows the equipment required for testing fiber
in Far End Source mode.
Figure 15. Equipment for Testing in Far End Source Mode (1 Jumper Method)
amd51f.eps
A
Tester and smart remote with fiber modules and
connector adapters installed (match connector adapters
to the connectors in the link)
B
Memory card (optional)
C
Two AC adapters with line cords (optional)
D
Test reference cord. Match the fiber to be tested. SC
connector at one end. Match the link connectors at the
other end.
E
Test reference cord. Match the fiber and connectors in
the link.
F
Singlemode adapter of the appropriate type.
G
Mandrel. Recommended when testing multimode
fiber with a DTX-MFM2 module. See page 12.
H
Fiber cleaning supplies
I
A microscope for inspecting fiber connectors (the
FT500 FiberInspector Mini Video Microscope is shown)
Downloaded from Elcodis.com electronic components distributor