Specications
General Features
Input voltage ................................. Up to 250 V (single phase system) /
up to 480 V (three phase system),
50/60 Hz, max 10 A
Internal power consumption .........3 W max.
FEV300-CON-TY2 Plug ............... AC charging mode 3, suitable to
IEC 62196-2 type 2 socket outlet or xed
cable with vehicle connector (type 2, 7P
three-phase)
FEV300-CON-TY1 Plug ............... AC charging mode 3, suitable to
IEC 62196-2 type 1 or SAE J1772 with
vehicle connector (type 1, 5P
single-phase)
Dimensions (H × W × D) .............. 110 mm × 45 mm × 220 mm
(4.3 in × 1.8 in × 8.7 in) length without
connection cable and test cable
Weight (including type 1 or
type 2 connection cable) ..............Approx. 1 kg (2.2 lb)
Safety standards ........................... IEC/EN 61010-1, pollution degree 2
IEC/EN 61010-2-030, CAT II 300 V,
protection class II
Ingress protection ......................... IEC 60529: IP54 (housing)
IEC 60529: IP54 (Measuring terminals
with protection caps in place, connector/
plug in connected condition or with
protection caps in place, otherwise IP20)
Operating temperature .................-20 °C to 40 °C (-4 °F to 104 °F)
Storage temperature ....................-20 °C to 50 °C (-4 °F to 122 °F)
Operating humidity range ............. 10 % to 85 % relative humidity
non-condensing
Storage relative humidity ..............0 % to 85 % non-condensing
Operating altitude .........................2000 m (6561 ft) max.
Functions
PE Pre-Test................................... Visible indication >50 V AC/DC between
PE conductor and touch sensor
PP Simulation ...............................Open, 13 A, 20 A, 32 A, 63 A
CP States ......................................State A, B, C, D
CP Error state “E” ......................... On/o󰀨 (CP signal short-circuited to PE)
PE Error state "F" (Earth fault) .....On/o󰀨 (interruption of PE conductor)
Outputs (for test purpose only)
Measuring terminals
L1, L2, L3, N, PE .......................... Max. 250/480 V, max. 10 A
CP signal output terminals ........... Approx. +/-12 V
Caution: In case of wrong wiring or error of the charging station these terminals
may be hazardous.