Do you have a question about the Fluke 5500A and is the answer not in the manual?
Type | Multi-Product Calibrator |
---|---|
Resistance Range | 0 to 1100 MΩ |
Accuracy | Varies depending on function and range |
Display | Backlit LCD |
Interface | RS-232, IEEE-488 |
Power Supply | 100 V to 240 V AC, 50/60 Hz |
Weight | 35 lbs |
Phase | Single phase |
Voltage DC Range | 0 to ±1020 V |
Details specifications for the 5500A Calibrator, valid after warm-up and within specified temperature ranges.
Details specifications for DC voltage outputs, including ranges, absolute uncertainty, stability, resolution, and maximum burden.
Details specifications for DC current outputs, including ranges, absolute uncertainty, compliance voltage, and maximum inductive load.
Details specifications for resistance outputs, including ranges, uncertainty, resolution, and allowable current.
Details specifications for AC sinewave voltage outputs, including ranges, frequency, uncertainty, resolution, and maximum burden.
Details specifications for AC sinewave current outputs, including ranges, frequency, uncertainty, resolution, compliance voltage, and maximum inductive load.
Details specifications for capacitance outputs, including ranges, uncertainty, resolution, and frequency.
Explains the software-based calibration process involving outputting values and entering measured results.
Details the steps for calibrating DC voltage outputs, including test points and required measurements.
Details the steps for calibrating AC voltage outputs, including test points and required measurements.
Details the steps for calibrating DC current output using precision DMM and shunts.
Details the steps for calibrating AC current output using a Fluke 5790A or equivalent.
Details the steps for calibrating resistance output using a precision DMM and four-wire connections.
Details the steps for calibrating capacitance output using an LCR meter.
Tests DC voltage accuracy at the NORMAL terminals.
Tests DC voltage accuracy at AUX terminals with a lower voltage at NORMAL terminals.
Tests DC current accuracy at the 5500A Calibrator front panel AUX terminals.
Verifies the accuracy of synthesized resistance at the 5500A Calibrator front panel NORMAL terminals.
Tests the accuracy of AC voltage at the 5500A Calibrator front panel NORMAL terminals.
Tests the accuracy of AC voltage at the 5500A Calibrator front panel AUX terminals.
Tests the accuracy of AC current at the 5500A Calibrator front panel AUX terminals.
Verifies the accuracy of synthesized capacitance output at the 5500A Calibrator front panel AUX terminals.
Tests the amplitude accuracy of DC volts at NORMAL terminals with DC I at AUX terminals.
Tests the amplitude accuracy of DC current output at AUX terminals with DC voltage at NORMAL terminals.
Tests current outputs at AUX terminals in the presence of high voltage.
Tests voltage outputs at NORMAL terminals in the presence of high current.
Tests the accuracy of AC power output at high power levels.
Checks amplitude accuracy of AC voltage squarewave at NORMAL terminals.
Checks amplitude accuracy of AC voltage squarewave at AUX terminals.
Explains the use of internal software self-testing capabilities to isolate faulty modules.
Provides a list of error messages to help determine suspect assemblies and circuits during diagnostics.
Details specifications specific to the SC600 Option, including voltage and square wave signal characteristics.
Details voltage specifications for the SC600 Option, including range, resolution, uncertainty, and sequence.
Details edge specifications for the SC600 Option, including rise time, amplitude range, resolution, aberrations, and duty cycle.
Details leveled sine wave specifications for the SC600 Option, including amplitude, frequency, and distortion.
Details procedures for calibrating the SC300 at the user's site, recommending factory calibration if possible.
Procedure for calibrating AC Voltage, requiring DC Voltage calibration first.
Procedure for calibrating the Wave Generator function using HP 3458A for measurements.
Procedure to verify leveled sine wave amplitude using 5790A AC Measurement Standard.
Details specifications specific to the SC300 Option, including voltage function characteristics.
Details voltage specifications for the SC300 Option, including range, resolution, uncertainty, and sequence.
Details edge specifications for the SC300 Option, including amplitude, resolution, aberrations, and duty cycle.
Details leveled sine wave specifications for the SC300 Option, including amplitude, frequency, and distortion.
Procedure for calibrating DC Voltage using HP 3458A, including setup and adjustment steps.
Procedure for calibrating edge amplitude using HP 3458A and 50 Ohm termination.
Procedure for calibrating leveled sine wave amplitude using 5790A AC Measurement Standard.
Procedure for verifying DC Voltage function using HP 3458A.
Procedure for verifying AC voltage amplitude using HP 3458A.
Procedure for verifying AC voltage frequency using PM 6680 Frequency Counter.
Procedure for verifying edge amplitude using HP 3458A and 50 Ohm termination.
Procedure for verifying edge frequency using PM 6680 Frequency Counter.
Procedure for verifying edge duty cycle using PM 6680 Frequency Counter.
Procedure to test edge function's rise time using an oscilloscope.
Procedure to verify leveled sine wave frequency using PM 6680 Frequency Counter.