Fluke 5700A Series User Manual

Fluke 5700A Series
576 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
®
5700A/5720A Series II
Multi-Function Calibrator
Service Manual
PN 601630
June 1996 Rev. 2, 3/05
©1996, 2002, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A.
All product names are trademarks of their respective companies.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Fluke 5700A Series and is the answer not in the manual?

Fluke 5700A Series Specifications

General IconGeneral
TypeMultifunction Calibrator
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity10% to 90% non-condensing
Frequency Range10 Hz to 1 MHz
AccuracyVaries by function and range. See manufacturer's specifications for details.
Output StabilityVaries by function and range. See manufacturer's specifications for details.
Power Requirements50 Hz to 60 Hz

Summary

Chapter 1 Introduction and Specifications

1-1. Introduction

Provides an overview of the calibrator's capabilities and features.

1-24. Specifications

Details electrical and performance specifications for the calibrator, including confidence levels.

Chapter 2 Theory of Operation

2-2. Calibrator Overview

Describes the calibrator's internal architecture, microprocessor control, and diagnostic capabilities.

2-9. Functional Description Presented by Output Function

Explains the operation of each output function, detailing assembly interactions.

Chapter 3 Calibration and Verification

3-5. Calibration

Outlines procedures for calibrating the instrument to external standards and performing checks.

3-6. Calibrating the 5700A/5720A Series II to External Standards

Details the connection and process for calibrating using external standards like voltage and resistance.

Chapter 4 Maintenance

4-2. Cleaning the Air Filter

Instructions for cleaning the calibrator's air filter to prevent overheating and maintain performance.

4-5. Access Procedures

Outlines safety precautions and methods for accessing internal components for servicing.

Chapter 5 Troubleshooting

5-1. Introduction

Introduces troubleshooting guidance for isolating faulty modules using diagnostic fault codes.

5-2. Interpreting Diagnostic Fault Codes

Explains how to interpret diagnostic fault codes to identify instrument issues and faulty assemblies.

Chapter 6 List of Replaceable Parts

6-2. How to Obtain Parts

Provides information on ordering replacement electrical components, including necessary order details.

6-6. Parts List

Lists all replaceable parts for the 5700A/5720A Series II calibrators with Fluke stock numbers.

Chapter 7 Schematic Diagrams

7-3. A3 Analog Motherboard PCA

Provides a schematic diagram of the Analog Motherboard PCA, detailing component locations and connections.

7-4. A4 Digital Motherboard PCA

Provides a schematic diagram of the Digital Motherboard PCA, illustrating component layout and interconnections.