Introduction and Specifications
Additional Specifications
1
1-29
1-24. AC Voltage, Squarewave Characteristics
Risetime
@ 1 kHz
Typical
Settling
Time
@ 1 kHz
Typical
Overshoot
@ 1 kHz
Typical
Duty Cycle Range Duty Cycle Uncertainty
[1]
<1 µs <10 µs to 1%
of final value
<2% 1% to 99%, <3.3 V p-p,
0.01 Hz to 100 kHz
± (0.8% of period +140 ns)
for frequencies >10 kHz;
+ (0.8% of period + 2 µs)
for frequencies 10 kHz.
[1] For duty cycles of 10.00% to 90.00%.
1-25. AC Voltage, Trianglewave Characteristics (typical)
Linearity to 1 kHz Aberrations
0.3% of p-p value, from 10% to 90% point <1% of p-p value, with amplitude >50% of range
1-26. AC Current (Sinewave) Extended Bandwidth Specifications
Ranges Frequency
1-Year Absolute Uncertainty,
tcal ± 5 °C,
± (% of output + % of range) [2]
Maximum
Current
Resolution
%Output %Range
All current ranges, <330 mA 0.01 to 10 Hz 5.0% 0.5% 2 digits each
range
10 to 10 kHz (See AC Current (Sinewave) Specifications)