ScopeMeter
®
Test Tool 190 Series II
Fluke 190-062, -102, -104, -202, -204, -502, -504
8VHUV0DQXDO

Table of Contents

Other manuals for Fluke ScopeMeter 190-204

Question and Answer IconNeed help?

Do you have a question about the Fluke ScopeMeter 190-204 and is the answer not in the manual?

Fluke ScopeMeter 190-204 Specifications

General IconGeneral
Bandwidth200 MHz
Channels4
Sample Rate2.5 GS/s
Memory Depth10, 000 points per channel
Safety RatingCAT III 1000 V / CAT IV 600 V
ConnectivityUSB
Battery Life4 hours
Input Impedance1 MΩ
Maximum Input Voltage1000 V
Operating Temperature0 °C to +40 °C
Storage Temperature-20 °C to +60 °C
Weight2.2 kg

Summary

Using the Scope and Meter

Powering the Test Tool

Procedure to turn on the test tool using the power adapter.

Input Connections

Describes how to connect probes to the test tool's BNC and banana jack inputs.

Displaying an Unknown Signal with Connect-and-View™

Using Connect-and-View to automatically optimize settings for unknown signals.

Making Automatic Scope Measurements

How to display numeric readings for measurements like Hz and Peak-Peak.

Using The Recorder Functions

Using Replay, Zoom and Cursors

Triggering on Waveforms

Setting Trigger Level and Slope

Adjusting trigger parameters for stable waveform display.

Maintaining the Test Tool

Calibrating the Voltage Probes

Procedure to calibrate voltage probes for accurate measurements.

Specifications

Oscilloscope

Detailed technical specifications for the oscilloscope.

Automatic Scope Measurements

Specifications for automated measurement functions.

Max. Input Voltages

Maximum input voltage limits by CAT rating.

Safety Instructions

Safety Precautions

Essential safety measures to prevent injury or damage.

Performance Verification

Scope Input A, B, C, D Tests

Verification procedures for scope inputs A, B, C, D.

Meter Tests

Procedures for verifying meter functions.

Calibration Adjustment

Warming-Up and Pre-Calibration

Steps for warming up and pre-calibrating the instrument.

Input A LF-HF Gain

Calibration procedure for Input A's LF-HF gain.

Multimeter Volt Gain

Calibrating voltage gain for multimeter functions.

Probe Calibration

Procedure for calibrating the voltage probes.

Disassembly

Open the Test Tool, Remove the Battery Pack

Steps to open the instrument and remove the battery.