Thermal Imagers
Detailed Specifications
17
Detailed Specifications
Temperature Measurements
Temperature Range (not calibrated below -10 °C)
TiR and TiR1 ................................................. -20 °C to +100 °C
Ti10 ...............................................................-20 °C to +250 °C
Ti25 ...............................................................-20 °C to +350 °C
Accuracy
TiR and Ti10..................................................±5 °C or 5 % (whichever is greater)
TiR1 and Ti25................................................ ±2 °C or 2 % (whichever is greater)
Measurement Modes .........................................Smooth Auto-Scaling and Manual
Scaling
On-screen Emissivity Correction........................(Ti25 and TiR1 Only)
Imaging Performance
Field of View......................................................23 ° x 17 °
Spatial Resolution (IFOV) ..................................2.5 mRad
Minimum Focus Distance
Thermal Lens................................................. 15 cm (approx. 6 in)
Visible (Visual) Light Lens.............................. 46 cm (approx. 18 in)
Focus ................................................................ Manual
Image Frequency............................................... 9 Hz refresh rate
Detector Type....................................................160 X 120 Focal Plane Array,
uncooled microbolometer
Infrared Lens Type............................................. 20 mm EFL, F/0.8 lens
Thermal Sensitivity (NETD)
Ti10 ...............................................................0.2 °C at 30 °C (200 mK)
Ti25 ...............................................................0.1 °C at 30 °C (100 mK)
TiR................................................................. 0.1 °C at 30 °C (100 mK)
TiR1...............................................................0.07 °C at 30 °C (70 mK)
Infrared Spectral Band....................................... 7.5 μm to 14 μm
Visual Camera...................................................640 x 480 resolution
Image Presentation
Palettes
TiR and Ti10..................................................Ironbow, Blue-Red, High Contrast,
Grey
TiR1 and Ti25................................................ Ironbow, Blue-Red, High Contrast
Amber, Hot Metal, Grey
Level and Span
Smooth Auto-Scaling and Manual Scaling of level and span
Minimum Span (in manual mode)