EasyManua.ls Logo

Fluke Ti9 - Specifications; General Specifications

Fluke Ti9
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TiR Users Manual
General Specifications
Temperature
Operating.............................................................
-10 C to 50 C (14 F to 122 F)
Storage................................................................
-20 C to 50 C (-4 F to 122 F)
without batteries
Charging..............................................................
0 C to 40 C (32 F to 104 F)
Relative Humidity
..................................................
10 to 90 % non-condensing
Display
....................................................................
640 x 480 Color LCD, approx. 2” X 3”
(Landscape orientation) with Backlight
Controls and Adjustments
(selectable Bright or Auto)
User selectable temperature scale (C/F)
Language selection
Time/Date set
Software .................................................................SmartView
®
full analysis and reporting
software included
Power
Battery .................................................................Internal rechargeable battery pack
Battery Life ..........................................................3 to 4 hours continuous use (assumes
50 % brightness of LCD)
Battery Charge Time ...........................................2 hours full charge with ac adapter or
dc car charger
AC Operation/Charging .......................................AC adapter/charger (110 220 Vac,
50/60 Hz). Charges battery while
imager is operating. Universal ac
mains adapters included.
Power Saving ......................................................Sleep Mode activated after 5 minutes
of inactivity
Automatic Power Off after 30 minutes
of inactivity
Vibration .................................................................2 G, IEC 68-2-29
Shock......................................................................25 G, IEC 68-2-6
Drop ........................................................................2 meter drop, all sides