IMPORTANT NNOTES
This fire is an Inset Live Fuel Effect Gas Fire providing radiant warmth. It is designed to operate on Natural Gas
only.
It is the LAW that all gas appliances and fittings are installed by a competent person (such as a CORGI registered
fitter) and in accordance with the Gas Safety (Installation and Use) Regulations 1998, the relevant British
Standards for Installation, Codes of Practice and in accordance with the Manufacturers’ Instructions. The
installation shall also be carried out in accordance with the following regulations:
The Building Regulations issued by the Department of the Environment, the Building Standards (Scotland)
(Consolidation) Regulations issued by the Scottish Development Department.
BS 5871 part 2
BS 5440 part 1
BS 1251
BS 6891
BS 6461 part 1
Failure tto ccomply wwith tthese rregulations ccould llead tto pprosecution aand ddeem tthe wwarranty
invalid.
This a
appliance mmust bbe iinstalled iin aaccordance wwith tthe rrules iin fforce aand uused oonly iin aa
sufficiently vvent
ilated sspace.
Consult aall iinstructions bbefore iinstallation aand uuse oof tthis aappliance.
This aappliance iis
ffree ffrom aany aasbestos mmaterial. RRefractories aand ccoal bbed aare cconstructed
from cceramic ffibre.
1
Section
1.0
2.0
3.0
4.0
4.1
5.0
6.0
7.0
7.1
8.0
8.1
8.2
8.3
Contents
Important Notes
Appliance Data
Installation Requirements
Site Requirements
Debris Collection Space
Ventilation
Flue Box
Unpacking the Appliance
Component Checklist
Installation of Appliance
Preparing the Appliance
Preparing the Opening
Gas Supply Routing
Page NNo.
1
2
2
3
4
4
4
4
5
5
5
5
6
Section
8.4
8.5
9.0
10.0
11. 0
11.1
11. 2
11. 3
12.0
12.1
13.0
14.0
15.0
Contents
Cable Fixing
Fitting the Burner Tray
Fuel Bed Layout
Fitting the Fireframe
Testing and Commissioning
Operating the Appliance
Spark Failure
Setting Pressure
Spillage Monitoring System
Testing for Spillage
Briefing the Customer
Servicing
Troubleshooting Guide
User Instructions
Page NNo.
6
7
7
8
8
8
8
8
9
9
9
10
11
Note - FFor RRepublic oof IIreland, rreference
should bbe mmade tto tthe rrelevant sstandards
governing iinstallation
, pparticularly iin rregard
to fflue ssizing aand vventilation. SSee IIS813,
ICP3, IIS327 aand aany oother rrules iin f
force.