4 12CI400A • 12HI400A 220 V 60 Hz/230 V 50 Hz Dispensers
Speci cations
air exhaust
407 mm
(16
"
)
102 mm
(4
"
)
3/8
" FPT
water inlet
3/4
" FPT drain
597 mm
(23.5
"
)
458 mm
(18
"
)
826 mm
(32
"
)
air
intake
power cord
Front View Side View Rear View
575 mm
(22.625
"
)
Electrical
220 V 60 Hz, 1 phase, 6.5A
230 V 50 Hz, 1 phase, 6.5A
Furnished with 1.8m (6 ft) power cord.
Ambient
Air temp 38 C/100 F Max. 10 C/50 F Min. (Best performance below 27 C/80 F)
Water temp 32 C/90 F Max. 4 C/40 F Min. (Best performance below 21 C/70 F)
Water pressure 5Bar Max./70 P.S.I. 0.7 Bar/10 P.S.I. Min.
Plumbing
C/E12CI400A C/E12HI400A
Dispenser drain 3/4" FPT 3/4" FPT
Water inlet 3/8" FPT 3/8" FPT
Note: Water shut-off recommended within 3m (10 ft) of dispenser. Drain to be hard-piped and insulated. Maintain
at least 20mm per 1m run (1/4" per foot) of slope.
Ventilation clearances
6" (153mm) on right side of dispenser, 6" (153mm) at top for ventilation and 12" (305mm) at top recommended for
service.
Note: Do not block right side air intake or top air exhaust.
Dry weight
79.4kg (175 lbs)