5. Automatic Closing
NOTE: We recommend that Photocells (Safety Beam) be used in any
installation setup where the Auto-Close function is enabled.
The Maximum time is 9 minutes. To disable Auto
Close, set time to zero (0).
c) Press SET button to confirm the your selected time.
6. Photocells (safety beam)
NOTE: Make sure the photocell has been correctly installed and uses
Normally Closed contacts to the accessory terminals of the opener
(Figures 13 & 14)
Also note that the photocell function must be disabled if NO
photo beams are fitted, otherwise the door cannot be closed,
and the LED will blink once time as an indication.
a) Press and hold the DOWN button until 11 appears on the
display. To enable the photocell option, press UP again, the
display will indicate an H (enabled) or press DOWN button to
disable photocells (11 will be displayed).
b) Press SET to confirm your choice.
7. Open / Stop / Close Terminals
The O/S/C facility can be used for an external push button switch to
operate the opener. The switch must have voltage free
normally open contacts (Figure 16)
Inease A/C time
Decrease A/C time
Auto Close enabled
Auto Close disabled
Photocell enabled
Photocell disab
led
a) Press and hold the UP button until a horizontal bar is
indicated on the display. Now press UP button once to set
the auto-close time (in minutes).
b) Press the UP button to increase the time, or the DOWN
button to decrease the time.