Parameter Range Description
Default
Setting
AHT -50 … 110° Condenser alarm temperature (if 'DI2' = 'T3'). 65
ACC ‘0 … 52 weeks
Condenser cleaning period.
(With ‘ACC’ = ‘0’ condenser cleaning alarm is disabled).
0
IISM
Switch over method to second parameter set:
NON
NON Second parameter set is excluded (the following parameter will be 'SB').
MAN Second parameter set is activated / deactivated by button 'M'.
DI2 Second parameter set activated by 'DI2' input ('DI2' = 'IISM').
ATM = 'ABS' or 'REL'
IISL -50 … IISH Minimum limit for 'IISP' setting. 1
IISH IISL … 110° Maximum limit for 'IISP' setting. 1
IISP IISP … IISH Temperature setpoint to be achieved in 'Mode 2'. 1
IIHY 1 … 10° Off / On thermostat differential in 'Mode 2'. 3
IIFC
Evaporator fan mode during 'Mode 2' thermostatic control:
NON
NON Fan(s) run continuously.
TMP
Temperature based control. When compressor is on, fans are on. When
compressor is off, fans run as long as temperature difference Te-Ta >
'FDT'. Fans on again with 'FDH'.
TIM
Time based control. When compressor is on, fans are on.
When compressor is off, fans in accordance to parameters
T1’, ‘FT2’ and ‘FT3’.
IIDF 0 … 99 hours Time interval between defrosts in ‘Mode 2’. 6
SB
Standby button operation:
YESYES Standby button enabled.
NO Standby button disabled.
DI1
Congurable digital input operation:
NON
NON Digital input not activated.
DOR Door switch input.
ALO Alarm ('ALr' displayed) when contact opens.
ALC Alarm ('ALr' displayed) when contact closes.
D12
Congurable digital input operation:
NON
NON Digital input not activated.
DOR Door switch input.
ALO Alarm ('ALr' displayed) when contact opens.
ALC Alarm ('ALr' displayed) when contact closes.
PSP Allows control via potentiometer.
IISM Operates 2nd parameter set when contact closes.
T3 Allows for 3rd temperature probe function.
DI2 = 'T3'
T3
T3 probe function (only when 'DI2' = 'T3'):
DSPDSP T3 probe temperature displayed.
CND Condenser temperature measurement.
OS3 -12.5 … 12.5°C T3 probe temperature offset (only when 'DI2' = 'T3'): 0
DI2 = 'PSP'
PSL -50 … 70°C Minimum setpoint adjusted by potentiometer (only when 'DI2' = 'PSP'): 10
PSR 0.0 … 15.0°C
Range of setpoint (hysteresis) for potentiometer (only when 'DI2' =
'PSP'):.
10