PR .T : FG016122
USE AND INSTALLATION HANDBOOK
Data : 03/04/17
Rev. 01 Sw. 1.A
Question and Answer IconNeed help?

Do you have a question about the Fourgroup Xtreme Series and is the answer not in the manual?

Fourgroup Xtreme Series Specifications

General IconGeneral
BrandFourgroup
ModelXtreme Series
CategoryControl Panel
LanguageEnglish

Summary

Warnings and Safety

Installation Guide

Line of Supply Current Connection

Instructions for connecting the main power supply to the control panel.

Line of Motor Power Supply Connection

Guidelines for connecting the motor power supply and checking rotation direction.

Light Indications and Buttons

Parameter Setting Procedures

General Settings Configuration

Enable 4-20mA Sensor Input

Activates/deactivates the 4-20mA signal reading device for operation.

System Password Setting

Allows the user to set/modify the password for programming menu access.

Pump Settings Configuration

Pump 1 Configuration

Allows setting all parameters related to pump 1.

Pump 1 Alarm Delay Settings

Sets delays for maximum/minimum current and Coso alarms.

Maximum Continuous Operation

Enables/disables and sets time limit for continuous pump operation alarm.

Maximum Starts Per Minute

Enables/disables and sets limit for pump starts per minute.

Maximum Starts Per Hour

Enables/disables and sets limit for pump starts per hour.

Klixon Intervention Limits

Enables/disables and sets limit for pump Klixon events.

Service Request Configuration

Enables/disables and sets working hours for pump service maintenance alarm.

Automatic Pump Parameter Setting

Automatically sets main electrical parameters for pump 1.

Pump 1 Current Limits

Sets the maximum and minimum allowed current consumption for pump 1.

Pump 1 Minimum Coso Setting

Sets minimum allowed Coso value for pump 1 (dry running indication).

Operating Program Modes

Program DARK Mode

Mode for waste/clean water systems, pump starts controlled by float switch.

Program CLEAN Mode

Mode for clean/waste water systems, controlled by float/pressure switches.

Program DIGIT Mode

Mode controlled by 4-20mA signal for level/pressure.

Program PAUSE/WORK Mode

Mode managing pump operation with defined pause and work times.

Operating Mode (Empty/Fill) Settings

Sets float switch or sensor location for operating modes.

Enable Operating Program Modes

Enables or disables specific operating programs (DARK, CLEAN, DIGIT).

Pause/Work Timing Configuration

Configures starting cycle, pause time, and work time for PAUSE/WORK mode.

Enable PAUSE/WORK Program

Activates/deactivates the PAUSE/WORK operating program for all pumps.

GSM Modem Settings

Alarm Settings and Outputs

Sound Alarm Configuration

Sets operating mode and alarm activation for the audio output.

Visual Alarm Configuration

Sets operating mode for the visual alarm output.

Restore Settings

Electric Connections

Maintenance Information

Spare Parts Information