36
Temp Fault
The inverter temperature is high.
• Please check if the environment temperature.
• Wait for a while to check if back to normal.
• Or seek for help from us.
Ground Fault
The ground connection is failed.
• Check the voltage of neutral and PE.
• Check AC wiring.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
Over Load Fault
Over load in on grid mode.
• Please check if the load power exceeds the limit.
• Or seek for help from us.
Eps Over Load
Over load in off grid mode.
• Please check if the eps load power exceeds the limit.
• Or seek for help from us.
Bat Power Low
The battery power is low.
• Wait the battery to be recharged.
• Or seek for help from us.
HW Bus Vol Fault
Bus voltage out of range detected by hardware.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
HW Pv Cur Fault
PV input current high detected by hardware.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
HW Bat Cur Fault
Battery current high detected by hardware.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
SCI Fault
The communication between master and manager is fail.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
MDSP SPI Fault
The communication between master and slave is fail.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.
MDSP Smpl Fault
The master sample detection circuit is failed.
• Disconnect PV, grid and battery, then reconnect.
• Or seek help from us, if not go back to normal state.