36
Temp Fault
The inverter temperature is high.
Please check if the environment temperature.
Wait for a while to check if back to normal.
Or seek for help from us.
Ground Fault
The ground connection is failed.
Check the voltage of neutral and PE.
Check AC wiring.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
Over Load Fault
Over load in on grid mode.
Please check if the load power exceeds the limit.
Or seek for help from us.
Eps Over Load
Over load in off grid mode.
Please check if the eps load power exceeds the limit.
Or seek for help from us.
Bat Power Low
The battery power is low.
Wait the battery to be recharged.
Or seek for help from us.
HW Bus Vol Fault
Bus voltage out of range detected by hardware.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
HW Pv Cur Fault
PV input current high detected by hardware.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
HW Bat Cur Fault
Battery current high detected by hardware.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
SCI Fault
The communication between master and manager is fail.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
MDSP SPI Fault
The communication between master and slave is fail.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.
MDSP Smpl Fault
The master sample detection circuit is failed.
Disconnect PV, grid and battery, then reconnect.
Or seek help from us, if not go back to normal state.