S Series User Manual www.fox-ess.com P a g e | 7
4. Technical Data
4.1 DC Input
Model
S700
S1000
S1500
S2000
S2500
S3000
S3300*
Max. recommended DC
power [W]
910
1300
1950
2600
3250
3900
4290
Max. DC voltage [V]
500
500
500
500
550
550
550
Nominal DC operating
voltage[V]
360
360
360
360
360
360
360
MPPT voltage range [V]
50-500
50-500
50-500
50-500
50-550
50-550
50-550
MPPT voltage range @ full
load [V]
80-450
110-450
160-450
210-450
240 -550
280-550
300-550
Max. input current [A]
12.5
Max. short circuit current [A]
15
Start output voltage [V]
60
No. of MPP trackers
1
Strings per MPP tracker
1
DC Switch
Optional
4.2 AC Output
Model
S700
S1000
S1500
S2000
S2500
S3000
S3300*
Rated output power [W]
700
1000
1500
2000
2500
3000
3300
Max. apparent AC power [VA]
800
1100
1650
2200
2750
3300
3300
Rated grid voltage and range [V]
220/230/240
Rated AC frequency and range
[Hz]
50/60
AC nominal current [A]
3.0
4.3
6.5
8.7
10.9
13.0
14.3
Max. output fault current [A]
3.5
4.8
7.2
9.6
12.0
14.3
14.3
THD
<3%
Displacement power factor
1 (Adjustable from 0.8 leading to 0.8 lagging)
Feed in phase
Single-phase
Over voltage category
PV: OVC II Mains: OVC III
4.3 Efficiency, Safety and Protection
Model
S700
S1000
S1500
S2000
S2500
S3000
S3300*
Max. MPPT efficiency
99.00%
99.00%
99.00%
99.00%
99.00%
99.00%
99.00%
Euro efficiency
96.50%
96.50%
96.50%
96.80%
96.80%
96.80%
96.80%
Max. efficiency
97.20%
97.20%
97.30%
97.40%
97.40%
97.40%
97.40%
Safety & Protection
DC Reverse-polarity protection
YES
Insulation monitoring
YES
DC injection monitoring
YES
AC Short-circuit protection
YES
Residual current detection
YES