19
5.9 Inverter Start-Up
Please refer to the following steps to start-up the inverter:
a) Check if device is fixed well on the wall;
b) Make sure all DC breakers and AC breakers are disconnected;
c) Ensure AC cable is connected to the grid correctly;
d) All PV panels are connected to inverter correctly; DC connectors that are not used should be sealed
by cover;
e) Turn on the external AC and DC connectors;
f) Turn the DC switch to the “ON” position (if equipped with DC switch on the inverter).
If the LED is not green, please check the below:
- All the connections are correct.
- All the external disconnect switches are closed.
- The DC switch of the inverter is in the “ON” position.
Note:
- When starting the inverter for the first time, the country code will be set by default to the local
settings. Please check if the country code is correct.
- Set the time on the inverter using the button or by using the APP.
Below are the three possible inverter states indicating that the inverter has started up successfully.
Waiting: Inverter is waiting to check the DC input voltage from panels is greater than 60V (lowest
start-up voltage) but less than 50V (lowest operating voltage), display will indicate the Waiting status and
green LED will flash.
Checking: Inverter will check DC input environment automatically when DC input voltage from the PV
panels exceeds 60V and PV panels have enough energy to start inverter, display will indicate the
Checking status and green LED will flash.
Normal: Inverter begins to operate normally with green light on. Meanwhile feedback energy to grid, LCD
displays present output power.
Note: You can go to the setting interface on the display to follow the instructions if it is the first time to
start up.
Complete inverter Start-up guide
After the initial start-up the inverter, display will go to the language settings page, short press to switch
language and long press to confirm selection. Once language set, display will guide to set the safety
regulation. Short press to switch safety regulation, and long press to confirm selection.
Note!
Please set-up the inverter if it is the first time to start-up. The above steps are for the
regular start-up of the inverter. If it is the first time to start up the inverter, you need to
carry-out the initial set-up of the inverter.