EasyManuals Logo

Franke FIG301S1 User Manual

Franke FIG301S1
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
15
ELECTRIC INDUCTION COOKING
SELECTED MODELS ONLY
SYSTEM TEMPERATURE CONTROL - INDUCTION
_______________________________________________________________________________________________________________________
Sensors situated inside the top constantly measures the temperature of the generator`s electronic circuits. In the event
of these circuits overheating the system reacts as follows:
When the first temperature is exceeded the system automatically switches off the booster. If activated, this initiates a
flashing `P` on the respective display showing that the booster cannot be responded to at the moment. When exceeding
a second medium temperature limit, the induction system reduces the power outlet to avoid any temperature increase.
When the temperature of the cooking zone exceeds a third temperature limit, the cooking zone is cut off automatically
from the induction system. The corresponding display indicates a flashing error code E2, possibly alternating with `H`.
The overheating of the circuits definitely indicates an anomaly, and means that the cook top has not been installed
properly or the openings for air circulation are not large enough.
ERROR TABLE
_______________________________________________________________________________________________________________________
CODE DESCRIPTION POSSIBLE CAUSE ACTION
ER 22 Key evaluation defective,
control unit cuts off after
3.5-7.5 sec
Short circuit or
discontinuation in the range of
the key evaluation
Contact Franke Service
03 9700 9100
ER 47 Communication error
between knob control and
induction
None or faulty
communication. Ensure that
connection cable is plugged
on correctly.
Contact Franke Service
03 9700 9100
ER 31 Configuration data incorrect Configuration of induction
necessary
Contact Franke Service
03 9700 9100
U400 Secondary voltage of the
power unit to high
(Primary>300v) Control unit
cuts off after 1 sec releasing
a permanent tone.
Control unit is wrongly
connected
Contact Franke Service
03 9700 9100
E2 Overheating of the induction
coils
Cooling down necessary Contact Franke Service
03 9700 9100
E5 Error on filter board Exchange filter board Contact Franke Service
03 9700 9100
E6 Error on Power board Exchange power unit Contact Franke Service
03 9700 9100
ER 20 Flash failure Exchange temperature sensor Contact Franke Service
03 9700 9100
E9 Coil temperature sensor
defective
Exchange temperature sensor Contact Franke Service
03 9700 9100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Franke FIG301S1 and is the answer not in the manual?

Franke FIG301S1 Specifications

General IconGeneral
BrandFranke
ModelFIG301S1
CategoryCooktop
LanguageEnglish

Related product manuals