LP Gas Conversion
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket, behind the range,
to the wall.
Reconnect the anti-tip bracket chains, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A. To range
B. Manual shutoff valve closed position
C. Gas supply line
A
B
C
Gas conversions from Natural gas to LP gas;
or from LP gas to Natural gas must be done
by a qualified installer.
To Convert Gas Pressure Regulator
1. Turn manual shutoff valve to the closed
position.
2. Unplug range or disconnect power.
Gas pressure regulator
Remove the access cap by using a wrench,
turning the access cap counterclockwise.
Unscrew part "F" from the cap. Look at part
"F" to locate the LP position.
Turn over the part "F" so the "LP arrow" is
showing on the top (D= LP position).
Screw part "F" from the cap.
Reinstall the cap onto the regulator.
Safety Instructions
Operating Instructions
Care and Cleaning
Installation InstructionsTroubleshooting Tips
28
Step 3 GAS CONVERSIONS
Skip to Step 4 if conversion is not necessary.
D. LP position
A. Access cap
B. Gasket
C. Gas pressure regulator
A
B
C
D
Part "F"
LP

Table of Contents