Error messages:
No Text in Signifi- Remedy
Display cance/
Causes
02 Temperature Ambient Set up tent
outside range temperature if necessary.
outside
permitted
range.
03 Resistance Electrical Check contact
outside resistance for firm
tolerance of fitting seating/dirt.
outside Maybe clean
tolerance. contacts, if
necessary
replace fitting.
04 Fitting winding Short circuit Replace
short circuit in the wire fitting,
winding of send in
fitting. for checks.
05 Fitting winding Current flow Check
open circuit interrupted. connection of
fusion plug on
fitting. If okay
replace the
fitting and send
in for checks.
06 Voltage Non Contact
outside permitted authorized
tolerance deviation of service station.
fusion
voltage.
08 Mains voltage Power Extension
outside range voltage cable too long
outside or cross
permitted section too
range during small. Check
fusion. voltage and
connections
of generator.
09 Frequency Frequency Check
outside range outside frequency
permitted of generator
range during voltage.
fusion.