Further error messages:
No Text in Signifi- Remedy
Display cance/
Causes
13 Mains failure Supply Check
voltage connentions.
interrupted
(e.g. power
cut during
fusion) or
too low.
15 Mains rating Power con- Please contact
exceeded sumption FRIATEC
of fitting service hotline:
exceeds +49 (0) 621
rating of the 486 1533
FRIAMAT
®
.
23 Generator- Generator Please contact
failure maybe not FRIATEC
suited for service hotline:
fusion work. +49 (0) 621
486 1533
xy* System error Please contact
FRIATEC
service hotline:
+49 (0) 621
486 1533
*: error messages with numbers not displayed in
above table.
37