EasyManuals Logo

Friedrich MR09C1H Service Manual

Friedrich MR09C1H
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #18 background imageLoading...
Page #18 background image
5.2 Electrical wiring
Outdoor Unit
These circuit diagrams are subject to change without notice, please refer to the one supplied with the unit.
Symbol Color symbol Symbol Color symbol
WH
WHITE
BN
BROWN
YE
YELLOW
BU
BLUE
RD
RED
BK
BLACK
YEGN
YELLOW GREEN PROTECTIVE EARTH
Indoor Unit
Indoor Unit
Schematic Diagram
L-OUT
L1
L1
0 0
RT1 RT2
M2
JUMP
CAP
TEM.SENSOR
ROOM
TUBE
TEM.SENSOR
FAN MOTOR
SWING MOTOR(U.D)
AP2
SWING-UD
K4
TUBEROOM
AC-L
PG
PGF
TR_OUT
TR_IN
TC
TRANSFORMER
13
DISPLAY
AP1
CN1
CN2
DISP-2DISP-1
M1
GG
XT1
W4 BU
W3 BN
N(1)
OUTDOOR UNIT
2
3
COM-OUT
W1 YEGN
W2 YEGN
N
W5 BK
I
II
ELECTRIC BOX
EVAPORATOR
Symbol Parts name Symbol Color symbol
L1 REACROR WH WHITE
PCB1~PCB2 PRINTED CIRCUIT BOARD YE YELLOW
S10/S11S40/S70/S80/S90 CONNECTOR RD RED
SAT OVERLOAD BN SAT OVERLOAD BN BROWN
COMP COMPRESSOR BU BLUE
PROTECTIVE EARTH BK BLACK
YEGN YELLOW GREEN
21
18

Other manuals for Friedrich MR09C1H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Friedrich MR09C1H and is the answer not in the manual?

Friedrich MR09C1H Specifications

General IconGeneral
BrandFriedrich
ModelMR09C1H
CategoryAir Conditioner
LanguageEnglish

Related product manuals