FAULT RECTIFICATION
© frifri Aro SA 7-2 OM - 1.0 - 25.10.2004
7.2 Safety thermostat
The deep fryer is equipped with a safety thermostat according to the current regulations.
The safety thermostat triggers at a temperature of 213 °C.
The safety thermostat switches off the deep fryer in the following situations:
Manual restarting of the deep fryer after an emergency cut-out by the safety thermostat:
CAUTION
• The control thermostat is defective.
• Part of the cable connection to the control thermostats is defective or has come loose.
• Part of the cable connection is not connected or falsely connected to the control thermostats.
• A power failure (mains) has occurred.
• The frying oil temperature is too high.
• The heating elements are heating “dry”, i.e. no frying liquid is present.
• Too little frying liquid is present.
ADVICE
• Clarify reason for the triggering of the safety thermostat.
• Actuate "On/Off" membrane switch.
• Actuate "Safety reset" membrane switch.