7.2 Safety thermostat
The deep fryer is equipped with a safety thermostat according to the current regulations.
The safety thermostat triggers at a temperature of 213 °C.
The safety thermostat switches off the deep fryer in the following situations:
Manual restarting of the deep fryer after an emergency cut-out by the safety thermostat:
CAUTION
The control thermostat is defective.
Part of the cable connection to the control thermostats is defective or has come loose.
Part of the cable connection is not connected or falsely connected to the control thermostats.
A power failure (mains) has occurred.
The frying oil temperature is too high.
The heating elements are heating “dry”, i.e. no frying liquid is present.
Too little frying liquid is present.
ADVICE
Clarify reason for the triggering of the safety thermostat.
Actuate "On/Off" membrane switch.
Actuate "Safety reset" membrane switch.