3. Refrigeration System:
Check that the compressor is functioning properly.
Check the starting relay, the overload and the capacitor. The Supplier recommends that the
compressor's starting relays and o
verloads be replaced every 3-4 ye
ars.
Check the fan motor condenser and fan motor evaporator.
Check that the thermostat or the electronic controller and its components are functioning properly.
Check the cooling performance of the ICM.
Check the cooling circuit using the appropriate leak detector in case there is any concern or sign
of refrige
rant lea
k.
APPENDIX C
GUIDE
LINES TO PREVENT CORROSION OF THE CABINET
1.
Avoid damages resulting from improper installation & operation, improper maintena
nce & cleaning,
as well as improper handling and
transportation, as per paragraphs 3, 4 and the App
endix A
above.
2.
Do not perform unauthorized adaptations, modifications or ad
justments to the cabinet.