V-09 - 03/2017 - PM/Stme - English - © FRIMA
Service report Error Effects and action
Service 110 Error in temperature
measuring system B1
Roasting applications possible
Model 112/112T/112L: No restrictions in the
right-hand pan
Call customer service
Service 111 Error in temperature
measuring system B2
Roasting applications possible
No restrictions in the left-hand pan
Call customer service
Service 121,... 128 Error in temperature
measuring system
B4, ... B11
Call customer service
Service 200 Flow sensor Please check the water inlet.
Cooking without automatic water inlet
possible
Service 201 Hot water flow sensor Please check the hot water inlet.
Cooking without automatic hot water inlet
possible
Service 220+222 Error in the locking
system
Model 112: No restrictions in the right-hand
pan
Call customer service
Service 221 + 223 Error in the locking
system (R)
No restrictions in the left-hand pan
Call customer service