Service reports
V-09 - 03/2017 - PM/Stme - English - © FRIMA
47 / 59
Service report Error Effects and action
Service 230 Error in the pan valve
drive
Automatic pan valve defect
Model 112: No restrictions in the right-hand
pan
Call customer service
Service 231 Error in the pan valve
drive (R)
Automatic pan valve defect
No restrictions in the left-hand pan
Call customer service
Service 240 + 242 Error in AutoLift-
system
Open left-hand cover and select AutoLift
again.
Do not close the cover manually during
AutoLift operation.
Service 241 + 243 Error in AutoLift
system (R)
Open right-hand cover and select AutoLift
again.
Do not close the cover manually during
AutoLift operation.