Service reports
48 / 59
V-09 - 03/2017 - PM/Stme - English - © FRIMA
Service report Error Effects and action
Service 252 Error in the cover
drive system
Call customer service
Service 260 Error in the pressure
measurement system
Pressure cooking (optional, not 112T/112L)
not possible.
Model 112: No restrictions in the right-hand
pan.
Call customer service
Service 261 Error in the pressure
measurement system
(R)
Pressure cooking (optional, not 112T/112L)
not possible
No restrictions in the left-hand pan
Call customer service
Service 262 Error in the pressure
system
Error in pressure cooking
Please check:
- Bound food product?
- Too little water?
- Overfilling?
- Steam nozzle contaminated?
Otherwise: Call customer service
Service 263 Error in the pressure
system (R)
Error in pressure cooking
Please check:
- Bound food product?
- Too little water?
- Overfilling?
- Steam nozzle contaminated?
Otherwise: Call customer service
Service 450 Bus error I/O A4 Call customer service
Service 460 Unit model not
defined
Call customer service
Service 480.1 -
480.5
System error No restrictions
Call customer service