EasyManua.ls Logo

Fronius FK 4000 - Connecting the Cooling Unit to the Power Source; Safety

Fronius FK 4000
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
Connecting the cooling unit to the power source
Safety
WARNING!
An electric shock can be fatal.
Before starting the work described below:
turn the power source mains switch to the "O" position
disconnect the power source from the mains
ensure that the power source remains disconnected from the mains until all work has
been completed
Connecting the
cooling unit to the
power source
Insert the M5 nuts provided (5) into the
hexagon-shaped openings on the fi-
xing bars (1) from the inside
Unscrew the TX 25 screws from the
protective cover on the underside of
the power source and remove the pro-
tective cover (if present)
(* Cooling unit scope of supply
Pull the power source connector (2) as
far out of the power source as possible
Position the power source above the
cooling unit
Connect the power source connector
(2) to the cooling unit connector (3)
CAUTION!
Risk of short circuit from kinked or damaged cables.
When positioning the power source, ensure that the cable is not kinked.
(1)
(5)
(*
1
2
(3)
(2)
3
4
5