EasyManua.ls Logo

Fronius Selectiva 1020E - Troubleshooting; Safety; Protection Devices

Fronius Selectiva 1020E
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
EN
Troubleshooting
Safety
Protection devic-
es
WARNING! An electric shock can be fatal. Before opening the device:
- Unplug the device from the mains
- Disconnect battery connection
- Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
- Using a suitable measuring instrument, check to make sure that electrically
charged parts (e.g. capacitors) have been discharged
CAUTION! Failure to connect a correctly-dimensioned earth lead may result in
serious injury or damage. The housing screws provide a suitable PE conductor
connection for earthing (grounding) the housing and must NOT be replaced by
any other screws that do not provide a reliable PE conductor connection.
Ready indicator flashing, error indicator flashing:
Cause: Mains fault - mains voltage outside the tolerance range
Remedy: Check mains conditions
Ready indicator lit, error indicator flashing:
Cause: Short circuit on the charging terminals or charger lead. Short circuit de-
tection on
Remedy: Check charger leads, contacts and battery poles
Cause: Battery overvoltage or undervoltage
Remedy: Select correct charging characteristic/function, or set correct battery volt-
age
Ready indicator flashing, error indicator lit:
Cause: Polarity reversal of charger leads. Reverse polarity protection has
tripped.
Remedy: Connect battery poles correctly
Charger switches off during charging:
Cause: Ambient temperature too high. Overtemperature protection active.
Remedy: Allow device to cool down. Charging will recommence automatically once
the device has cooled sufficiently. If not, have it checked by a workshop.