All inverters are designed to be dust-tight. However, in areas
with a heavy build-up of dust, the thermal efficiency may still be
impaired by dust forming on the cooling surfaces. Regular clean-
ing is necessary in such situations. We therefore recommend not
installing the inverter in areas and environments with high dust
accumulation.
Do not install the inverter in:
-
Greenhouses
-
Storage or processing areas for fruit, vegetables or viticul-
ture products
-
Areas used in the preparation of grain, green fodder or an-
imal feeds
Installation posi-
tion
The inverter is suitable for vertical installation on a vertical wall or
column.
The inverter is suitable for a horizontal installation position.
The inverter is suitable for installation on a sloping surface.
Do not install the inverter on a sloping surface with its connection
sockets at the top.
Do not install the inverter at an angle on a vertical wall or column.
Do not install the inverter horizontally on a vertical wall or pillar.
8