Technical data
Special voltages For devices designed for special voltages, the technical data on the rating plate applies.
For all machines with a permitted mains voltage of up to 460 V: The standard mains plug
allows the user to operate with a mains voltage of up to 400 V. For mains voltages up to
460 V fit a mains plug permitted for such use or install the mains supply directly.
TPS 2700
Mains voltage   3 x 400 V
Mains voltage tolerance   +/- 15 %
Mains frequency   50 / 60 Hz
Mains fuse protection   16 A slow-blow
Mains connection
 1)
Z
max
 at PCC
 2)
 = 95 mOhm
Primary continuous current
100% d.c. 
3)
6.6 A
Primary continuous power   4.5 - 8.7 kVA
Cos phi   0.99
Efficiency   87 %
Welding current range    
  MIG/MAG 3 - 270 A
  Rod electrode 10 - 270 A
  TIG 3 - 270 A
Welding current at
  10 min / 40 °C (104 °F)
40 % d.c. 
3)
270 A
   
60 % d.c. 
3)
270 A
   
100% d.c. 
3)
170 A
Welding voltage range according to standard characteristic
  MIG/MAG 14.2 - 27.5 V
  Rod electrode 20.4 - 30.8 V
  TIG 10.1 - 20.8 V
Max. welding voltage   34.6 V
Open circuit voltage   50 V
Degree of protection   IP 23
Type of cooling   AF
Insulation class   B
EMC emission class   A
Marks of conformity   CE, CSA
Safety symbol   S
Dimensions l x w x h 641.5 x 297.4 x 476.5 mm
25.26 x 11.71 x 18.76 in.
191
EN
Toowoomba Welding Supplies  :  tweld.com.au  :  Ph +61 7 4659 0044