TIG 3 - 500 A
Welding current at
  10 min/40 °C (104 °F)
40 % d.c. 
2)
500 A
   
60 % d.c. 
2)
450 A
   
100% d.c. 
2)
360 A
Welding voltage range according to standard characteristic
  MIG/MAG 14.2 - 39.0 V
  Rod electrode 20.4 - 40.0 V
  TIG 10.1 - 30.0 V
Max. welding voltage   49.2 V
Open circuit voltage   70 V
Degree of protection   IP 23
Type of cooling   AF
Insulation class   F
EMC emission class   A
Marks of conformity   CE, CSA
Safety symbol   S
Dimensions l x w x h 626 x 287 x 477 mm
24.65 x 11.30 x 18.78 in.
Weight   35.6 kg
78.5 lb.
1)
 connected to public grid at 230/400 V and 50 Hz
2)
 d.c. = Duty cycle
TS/TPS 5000 MV
Mains voltage   3 x 200-240 V
3 x 380-460 V
Mains voltage tolerance   +/- 10 %
Mains frequency   50 / 60 Hz
Mains fuse protection   63/35 A slow-blow
Mains connection
 1)
Restrictions possible
Primary continuous current
100% d.c. 
2)
10.1 - 36.1 A
Primary continuous power   12.4 - 13.9 kVA
Cos phi   0.99
Efficiency   88 - 91 %
Welding current range    
  MIG/MAG 3 - 500 A
  Rod electrode 10 - 500 A
  TIG 3 - 500 A
Welding current at
  10 min/40 °C (104 °F)
40 % d.c. 
2)
500 A
199
EN